Rev. bras. cir. cardiovasc ; 28(4): 462-469, out.-dez. 2013. ilus
Article in English | LILACS | ID: lil-703113

ABSTRACT

INTRODUCTION: In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. OBJECTIVE: To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. METHODS: To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min.) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. RESULTS: It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. CONCLUSIONS: Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM) is superior to the 21 AJ - 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves.


INTRODUÇÃO: A caracterização hidrodinâmica in vitro de próteses de válvulas cardíacas fornece informações importantes quanto ao seu funcionamento, sobretudo se realizada por meio de métodos não-invasivos de anemometria. Uma vez obtidos os perfis de velocidade para cada válvula, é possível compará-las quanto ao seu desempenho hidrodinâmico. Neste primeiro estudo experimental de anemometria laser com válvulas mecânicas, as simulações foram realizadas em bancada de testes para escoamento permanente. OBJETIVO: Comparar perfis de velocidade unidimensional no plano central de duas próteses aórticas de duplo folheto St. Jude (modelos AGN 21 - 751 e 21 AJ - 501) submetidas a um regime de fluxo permanente, para quatro seções distintas, três à jusante e uma à montante. MÉTODOS: Proporcionar condições de similaridade para o escoamento através de cada prótese, por meio de bancada hidrodinâmica para escoamento permanente (água, à vazão de 17 L/min.) e, por meio de anemometria laser unidimensional, obter os perfis de velocidades para as mesmas seções e varreduras. RESULTADOS: Verificou-se que as maiores velocidades correspondem à prótese de diâmetro interno menor e que as instabilidades do fluxo são maiores à medida que a seção de interesse encontra-se mais próxima da válvula. Também foram verificadas as regiões de recirculação, de estagnação do fluxo e de baixa pressão, além dos picos de velocidade para o escoamento em questão. CONCLUSÕES: Sob o aspecto hidrodinâmico e para todas as seções de interesse, foi possível concluir a preferência da válvula de modelo AGN 21 - 751 (RegentTM) sobre a 21 AJ - 501 (Master Series). Os resultados obtidos permitiram escolher, para os próximos trabalhos, um foco de estudo mais específico para regiões concretas dessas próteses.


Subject(s)
Blood Flow Velocity , Heart Valve Prosthesis , Hydrodynamics , Laser-Doppler Flowmetry/methods , Materials Testing , Medical Illustration , Models, Cardiovascular , Pressure , Prosthesis Design , Reproducibility of Results , Time Factors
3.
Rev. bras. cir. cardiovasc ; 27(4): 535-541, out.-dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-668115

ABSTRACT

INTRODUÇÃO: A circulação extracorpórea (CEC) é indispensável para a maioria das operações cardíacas, mas causa danos significantes ao sangue, dentre eles a hemólise. OBJETIVO: Quantificar as taxas de hemólise em diferentes tempos nas operações para revascularização do miocárdio com uso de CEC. MÉTODOS: Foram medidas as taxas de hemólise de 22 pacientes em 6 tempos distintos durante a revascularização do miocárdio com uso de CEC: T0 - antes do início da CEC, T1 - 5 minutos após o início da CEC, T2 - com 30 minutos de CEC, T3 - imediatamente antes do despinçamento da aorta, T4 - imediatamente antes da passagem do volume residual para o paciente e T5 - 5 minutos após o término da passagem do volume residual para o paciente. Foram calculadas as taxas de hemólise entre os intervalos de tempo: T0-T1; T1-T2; T2-T3; T3-T4 e T4-T5. RESULTADOS: Os primeiros 5 minutos após a CEC demonstraram maior taxa de hemólise (P = 0,0003) em comparação às outras taxas calculadas, representando 29% da hemólise total até T4 (imediatamente antes da passagem do volume residual para o paciente). CONCLUSÃO: Não foram observadas variações significantes nas taxas de hemólise durante a aspiração na raiz da aorta (P > 0,38) nem com o procedimento utilizado para a passagem do volume residual de sangue no circuito para os pacientes.


INTRODUCTION: Extracorporeal circulation (EC) is very important in cardiac surgery but causes significant damage to the blood, including hemolysis. OBJECTIVE: To quantify the rate of hemolysis at different times during EC in elective coronary artery bypass grafting. METHODS: We measured rates of hemolysis of 22 patients at 6 different times during myocardial revascularization during EC: T0 - before the start of EC, T1 - five minutes after of the EC initiation, T2 - 30 minutes of EC, T3 - immediately before the aortic unclamping, T4 - immediately before passage of the residual volume to the patient and T5 - five minutes after the passage of the residual volume to the patient. Rates of hemolysis were calculated between the intervals of time: T0-T1; T1-T2; T2-T3; T3-T4 and T4-T5. RESULTS: The first 5 minutes after the EC showed the highest rate of hemolysis (P = 0.0003) compared to the others calculated rates, representing 29% of the total haemolysis until T4 (Immediately before passage of the residual volume to the patient). CONCLUSION: There were no significant changes in the rate of hemolysis during the suction in the aortic root (P> 0.38), nor with the procedure used for the passage of the residual volume of blood in the circuit to the patient.


Subject(s)
Female , Humans , Male , Middle Aged , Coronary Artery Bypass/methods , Extracorporeal Circulation/adverse effects , Hemolysis/physiology , Analysis of Variance , Blood Specimen Collection/methods , Blood Specimen Collection/statistics & numerical data , Extracorporeal Circulation/methods , Statistics, Nonparametric , Time Factors
4.
Arq. bras. cardiol ; 99(5): 1031-1039, nov. 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-656642

ABSTRACT

FUNDAMENTO: O Transplante Cardíaco (TC) é uma alternativa para os indivíduos com doença cardíaca terminal. Na evolução pós-transplante, a ocorrência de episódios de Rejeição Cardíaca (RC) é evento frequente que aumenta a morbimortalidade, sendo necessário o emprego de exame não invasivo com boa acurácia para seu diagnóstico, pois a Biópsia Endomiocárdica (BEM) não é um procedimento isento de complicações. OBJETIVO: Comparar parâmetros obtidos com o princípio Doppler, entre os pacientes transplantados com RC (TX1) e os pacientes transplantados sem rejeição (TX0); utilizando como referência o Grupo Controle (GC) e observando o comportamento da função sistodiastólica ventricular esquerda expressa por meio do Índice de Performance Miocárdica (IPM). MÉTODOS: Foram realizados ecocardiogramas transtorácicos no período de janeiro de 2006 a janeiro de 2008, para a avaliação prospectiva de 47 pacientes, subdivididos em GC (36,2%), TX0 (38,3%) e TX1 (25,5%), comparando-se o IPM entre eles. Para a análise dos dados foram realizados os testes exato de Fisher e o não paramétrico de Kruskal-Wallis, ambos com nível de significância de 5%. RESULTADOS: Os grupos não diferiram em relação a idade, peso, altura e superfície corpórea. Quando comparado ao GC, TX0 e TX1 apresentaram alteração da função sistodiastólica ventricular esquerda, expressa como aumento do IPM, que foi mais intenso no TX1 [0,38 (0,29 - 0,44) X 0,47 (0,43 - 0,56) X 0,58 (0,52 - 0,74) p < 0,001]. CONCLUSÃO: O ecocardiograma mostrou-se como exame de boa acurácia na detecção das alterações da função sistodiastólica do coração transplantado; entretanto, não foi confiável como método substituto da BEM para o diagnóstico seguro de RC.


BACKGROUND: Heart transplantation is an alternative for individuals with end-stage heart disease. However, episodes of heart rejection (HR) are frequent and increase morbidity and mortality, requiring the use of an accurate non-invasive exam for their diagnosis, since endomyocardial biopsy (EMB) is not a complication-free procedure. OBJECTIVE: To compare the parameters obtained by use of Doppler echocardiography in a group of transplanted patients with HR (TX1) and another group of transplanted patients without rejection (TX0), having as reference a control group (CG) and observing the behavior of the left ventricular systo-diastolic function expressed as the myocardial performance index (MPI) METHODS: Transthoracic echocardiographies were performed from January 2006 to January 2008 to prospectively assess 47 patients divided into three groups: CG (36.2%); TX0 (38.3%); and TX1 (25.5%). The MPI was compared between the groups, and data were analyzed by use of Fisher exact test and nonparametric Kruskal-Wallis test, both with significance level of 5%. RESULTS: The groups did not differ regarding age, weight, height, and body surface. When compared to GC, TX0 and TX1 showed a change in the left ventricular systo-diastolic function, expressed as an increase in MPI, which was greater in TX1 [0.38 (0.29 - 0.44); 0.47 (0.43 - 0.56); 0.58 (0.52 - 0.74), respectively; p < 0.001]. CONCLUSION: Echocardiography was a very accurate test to detect changes in the systo-diastolic function of the transplanted heart; however, it did not prove to be reliable to replace BEM in the safe diagnosis of HR.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Graft Rejection , Heart Transplantation , Myocardial Contraction/physiology , Ventricular Dysfunction, Left , Ventricular Function/physiology , Age Distribution , Biopsy , Echocardiography, Doppler , Epidemiologic Methods , Graft Rejection/pathology , Heart Transplantation/pathology , Heart Ventricles/pathology , Sex Distribution , Stroke Volume , Time Factors , Ventricular Dysfunction, Left/physiopathology
5.
Rev. bras. cir. cardiovasc ; 27(3): 347-354, jul.-set. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-660804

ABSTRACT

INTRODUÇÃO: Uma grande variedade de técnicas e soluções é utilizada na preservação do coração durante o transplante, o que demonstra a falta de método ideal na prática clínica. A administração da cardioplegia de forma retrógrada propicia perfusão contínua, o que pode conferir melhor recuperação inicial do coração transplantado. O objetivo deste trabalho é descrever a experiência de um único centro onde todos os pacientes receberam a mesma solução de conservação de órgão e foram submetidos a microcardioplegia sanguínea retrógrada contínua durante o implante do enxerto e avaliar fatores de mortalidade precoce e tardia com a utilização desta técnica. MÉTODOS: Este é um estudo retrospectivo, observacional e descritivo, realizado em um único centro. RESULTADOS: No período do estudo, foram realizados 35 transplantes cardíacos, sendo que 15 (42,9%) pacientes encontravam-se em choque cardiogênico. A probabilidade de sobrevida foi 74,8±7,8%, 60,4±11,3% e 15,1±13,4% ao final de 1 ano, 5 anos e 10 anos de seguimento, respectivamente. O tempo médio de sobrevida foi de 96,6 meses. CONCLUSÃO: A utilização da solução cardioplégica para proteção de órgãos e a estratégia de iniciar a perfusão com microcardioplegia sanguínea retrógrada contínua forneceu proteção adequada.


BACKGROUND: Several techniques and cardioplegic solutions have been used for heart preservation during transplant procedures. Unfortunately, there is a lack of ideal method for myocardial preservation in the clinical practice. The use of retrograde cardioplegia provides continuous infusion of cardioplegic solution during the graft implantation. This strategy may provide better initial recovery of the graft. The objective of this study is to describe the experience of a single center where all patients received the same solution for organ preservation and were subjected to continuous retrograde blood microcardioplegia during implantation of the graft and to evaluate factors associated to early and late mortality with this technique. METHODS: This is a retrospective, observational and descriptive study of a single center. RESULTS: During the study period were performed 35 heart transplants. Fifteen (42.9%) patients were in cardiogenic shock. The probability of survival was 74.8±7.8%, 60.4±11.3% and 15.1±13.4% at 1 year, 5 years and 10 years of follow-up, respectively. The median survival time was 96.6 months. CONCLUSION: The use of myocardial protection with retrograde cardioplegic solution may reduce the risks associated morbidity due to cold ischemia time during the heart transplant, and we suggest that this benefit may be even greater in cases of cold ischemia time longer ensuring protection to the myocardium.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Cardioplegic Solutions , Heart , Heart Arrest, Induced/methods , Heart Transplantation/mortality , Organ Preservation/methods , Brazil , Epidemiologic Methods , Heart Transplantation/methods , Time Factors , Treatment Outcome
6.
Rev. bras. cir. cardiovasc ; 26(4): 559-564, out.-dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-614747

ABSTRACT

INTRODUÇÃO: Os resultados tardios da plastia mitral em pacientes reumáticos são controversos na literatura. OBJETIVO: Estudo observacional e prospectivo que avalia os resultados tardios e identifica os fatores associados à reoperação e à mortalidade em pacientes reumáticos submetidos à plastia da valva mitral. MÉTODOS: Incluídos somente os pacientes com valvopatia mitral reumática submetidos a plastia, com insuficiência tricúspide associada ou não. Excluídos os pacientes com outros procedimentos associados. Um total de 104 pacientes foi estudado. Sobrevida e reoperação foram avaliadas pela analise de Kaplan-Meier e regressão logística de Cox. RESULTADOS: O tempo de seguimento foi de 63 ± 39 meses (IC 95 por cento 36 a 74 meses). A classe funcional III e IV estava presente em 65,4 por cento dos pacientes no pré-operatório. Foram realizadas 33 plastias do anel posterior, 21 comissurotomias, 50 comissurotomias e plastias do anel posterior. Não houve mortalidade operatória e a tardia foi de três (2,8 por cento) pacientes. A reoperação tardia esteve associada à insuficiência mitral residual no pós-operatório (P<0,001), presença de hipertensão pulmonar no pré-operatório (P< 0,01), idade (P<0,04) e classe funcional no pós-operatório (P<0,001). No seguimento, a probabilidade de estar livre de reoperação com 5 e 10 anos foi de 91,2 ± 3,4 por cento e 71,1 ± 9,2 por cento, respectivamente. CONCLUSÃO: Os resultados tardios do reparo da valva mitral em pacientes reumáticos têm fatores associados à reoperação. O reparo da valva mitral reumática é seguro e com ótima sobrevida a longo prazo.


INTRODUCTION AND AIMS: The long-term results after surgical repair of rheumatic mitral valve remain controversial in literature. Our aim was to determine the predictive factors which impact the long-term results after isolated rheumatic mitral valve repair and to evaluate the effect of those factors on reoperation and late mortality. METHODS: One hundred and four patients with rheumatic valve disease who had undergone mitral valve repair with or without tricuspid valve annuloplasty were included. All patients with associated procedures were excluded. The predictive variables for reoperation were assessed with Cox regression and Kaplan Meier survival curves. RESULTS: The mean follow-up time was 63 ± 39 months (CI 95 percent 36 to 74 months). The functional class III and IV was observed in 65.4 percent of all patients. The posterior ring annuloplasty was performed in 33 cases, comissutoromy in 21 cases, and comissurotomy with posterior ring annuloplasty in 50 patients. There was no operative mortality. The late mortality was 2.8 percent (three patients). The late reoperation was associated with residual mitral valve regurgitation after surgery (P<0.001), pulmonary hypertension at the pre-operative time (P<0.001), age (P<0.04) and functional class at the post-operative time (P<0.001). We observed freedom from reoperation rates at 5 and 10 years of 91.2 ± 3.4 percent and 71.1 ± 9.2 percent, respectively. CONCLUSION: Repair of mitral valve in rheumatic valve disease is feasible with good long-term outcomes. Preoperative pulmonary hypertension, residual mitral valve regurgitation after surgery, age and functional class are predictors of late reoperation.


Subject(s)
Female , Humans , Male , Middle Aged , Heart Valve Diseases/mortality , Heart Valve Prosthesis Implantation/adverse effects , Hypertension, Pulmonary/complications , Mitral Valve Insufficiency/complications , Mitral Valve/surgery , Rheumatic Heart Disease/mortality , Epidemiologic Methods , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Preoperative Care , Risk Factors , Reoperation/statistics & numerical data , Rheumatic Heart Disease/surgery , Treatment Outcome
7.
Rev. bras. cir. cardiovasc ; 26(2): 164-172, abr.-jun. 2011. ilus, tab
Article in English | LILACS | ID: lil-597735

ABSTRACT

BACKGROUND: Myocardial infarction might result in dilated left ventricle and numerous techniques have been described to restore the original left ventricle shape and identify tools for late survival assessment. The aim of this study is to compare our experience with a modified Dor procedure using a rigid prosthesis to the septal anterior ventricular exclusion procedure (SAVE) for left ventricle restoration. The EuroScore index for prediction of late follow up survival was evaluated. METHODS: We evaluated 80 patients who underwent left ventricle restoration between 1999 to 2007 and eight patients were excluded with incomplete data. A modified Dor procedure with rigid prosthesis (MD group) was performed on 53 patients and 19 underwent the septal anterior ventricular exclusion procedure (SAVE group). The patients were classified according their left ventricle shape as type I, II or III. Kaplan-Meier and Cox proportional hazard ratio regressions analysis were performed to assess survival after both techniques and expected surgical mortality using EuroScore index ranking after 12 years of follow up. RESULTS: The operative mortality was comparable in both groups ranked by EuroScore index. The groups were comparable for all clinical data, except the MD group had more patients using intra-aortic balloon pumps before surgery, (5.7 percent vs. 0; P<0.01). Kaplan Meier analysis by left ventricle shape showed comparable survival for all patients, with slightly higher survival for type I. Kaplan Meier analysis of all death showed equivalent survival curves for both techniques after 12 years of follow up (71.5 ± 12.3 vs. 46.6 ±20.5 years; P=0.08). Kaplan Meier analysis of EuroScore index for all patients showed a difference between the three ranked categories, i.e., 0 to 10 percent, 11 to 49 percent and higher than 50 percent expected surgical mortality after 12 years of follow up (70.9 ± 16.2 vs. 67.5 ± 12.7 vs. 53.0 ± 15.5; P=0.003). CONCLUSION: The MD procedure showed consistent ejection fraction improvements after long term follow up. Survival was comparable for all ventricular types and for the MD and SAVE procedures. The EuroScore index is a useful index for late survival assessment of ventricular restoration techniques.


INTRODUÇÃO: O infarto do miocárdio pode levar à dilatação do ventrículo esquerdo e numerosas técnicas têm sido descritas para remodelar o ventrículo ao seu formato original. O objetivo deste estudo foi comparar nossa experiência com a cirurgia de Dor modificada, usando prótese rígida, com a técnica de exclusão septal ventricular anterior (SAVE). Foi avaliado também o EuroScore como índice preditivo da mortalidade tardia. MÉTODOS: Avaliamos 80 pacientes que foram submetidos a remodelamento ventricular entre 1997 e 2007. Oito pacientes foram excluídos por dados incompletos. A cirurgia de Dor modificada (grupo MD) foi constituída por 53 pacientes e 19 no grupo com exclusão septal anterior (grupo SAVE). Os pacientes foram classificados de acordo com o formato do ventrículo como tipo I, II ou III. Curvas de sobrevivência de Kaplan-Meier e regressão de Cox foram utilizadas para analisar a sobrevida nas duas técnicas e a mortalidade esperada foi avaliada utilizando o EuroScore para a mortalidade operatória e após 12 anos de seguimento. RESULTADOS: A mortalidade operatória foi comparável nos dois grupos quando avaliados pelo EuroScore. Os grupos foram comparáveis quanto a dados clínicos, com exceção, que o grupo MD apresentava maior número de pacientes com balão intra-aórtico no pré-operatório (5,7 por cento vs. 0; P<0,01). A curva actuarial considerando o formato dos ventrículos foi comparável avaliando-se todos os pacientes, sendo que o formato tipo I apresentou discreta melhor sobrevida após 12 anos de seguimento. As técnicas MD e SAVE demonstraram sobrevidas semelhantes após 12 anos de seguimento (71,5 ± 12,3 vs. 46,6 ±20,5 por cento; P=0,08). Avaliando o EuroScore para todos os pacientes, observamos que nas categorias utilizadas, ou seja, 0-10 por cento; 11-49 por cento e maior que 50 por cento de mortalidade esperada, a sobrevida após 12 anos de seguimento foi diferente (70,9 ± 16,2 vs. 67,5 ± 12,7 vs. 53,0 ± 15,5; P=0,003). CONCLUSÃO: A técnica MD demonstrou melhora consistente da fração de ejeção no seguimento tardio. As duas técnicas apresentaram sobrevida comparáveis. O EuroScore pode ser um índice útil para avaliação da sobrevida tardia.


Subject(s)
Animals , Cattle , Female , Humans , Male , Middle Aged , Bioprosthesis , Cardiac Surgical Procedures/methods , Heart Valve Prosthesis , Heart Ventricles/surgery , Ventricular Remodeling , Cardiac Surgical Procedures/mortality , Epidemiologic Methods , Pericardium
8.
Rev. bras. cir. cardiovasc ; 26(2): 205-212, abr.-jun. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-597740

ABSTRACT

INTRODUÇÃO: Bombas de roletes desempenham um papel importante na circulação extracorpórea. No entanto, a oclusão dos roletes das bombas deve ser realizada de forma adequada e estas podem ser ajustadas, principalmente por dois métodos: estático e dinâmico. OBJETIVO: Investigar como os perfusionistas brasileiros ajustam as bombas de rolete arterial em seus serviços e testar o uso de um Dispositivo Auxiliar de Calibração que facilita o ajuste pelo método de calibração dinâmica. MÉTODOS: Foi instalada uma bomba de roletes com os acessórios necessários para a realização de sua calibração pelos métodos de velocidade de queda (calibração estática) e calibração dinâmica durante o XXVIII Congresso Brasileiro de Circulação Extracorpórea. Foi solicitado aos perfusionistas que ajustassem uma bomba de roletes conforme procedimento normalmente utilizado em seu serviço. Após cada regulagem, foi medida a respectiva pressão pelo método de calibração dinâmica com o auxílio do dispositivo. O projeto foi aprovado pelo Comitê de Ética em Pesquisa da UNICAMP, sob Nº 1144/2010. RESULTADOS: Participaram da pesquisa 56 perfusionistas. A média das 56 medidas de pressão de calibração dinâmica foi 434 ± 214 mmHg; 76 por cento das medidas realizadas ficaram no intervalo preconizado para o uso da técnica de calibração dinâmica (entre 150 e 500 mmHg). CONCLUSÃO: Os perfusionistas brasileiros tendem a calibrar bombas de roletes com ajustes menos oclusivos. As amplitudes das medidas de pressão de calibração dinâmica tendem a ser menores para perfusionistas mais experientes. O dispositivo pode ser utilizado por perfusionistas para ajustar bombas de roletes com maior precisão e, principalmente, repetitividade e em alguns minutos.


INTRODUCTION: Roller pumps play an important role in extracorporeal circulation. However, occlusion of the rollers should be adequately performed and this can be adjusted mainly by two methods: static and dynamic. OBJECTIVE: To investigate how the Brazilian perfusionists adjust arterial roller pumps in their services and evaluate the application of a Device to Assist Calibration (DAC) that facilitates roller adjustment by the dynamic calibration method. METHODS: We installed a roller pump with accessories to perform adjustment by drop rate (static calibration) and dynamic calibration methods during the XXVIII Brazilian Congress of Extracorporeal Circulation. Perfusionists were asked to adjust the roller pump according to the procedure they usually do in their service. After each adjustment pressure was measured by dynamic calibration method with DAC. The research was approved by the Research Ethics Committee of UNICAMP, Nº 1144/2010. RESULTS: There were 56 perfusionists in this study. Pressure average of 56 measurements of dynamic calibration was 434 ± 214 mmHg; 76 percent of measurements were within the recommended range for the use of the dynamic calibration method (between 150 and 500 mmHg). CONCLUSION: Brazilian perfusionists tend to adjust roller pumps with less occlusive settings. The amplitudes of the dynamic calibration pressure tend to be smaller for more experienced perfusionists because their skills increase with time. The device can be used by the perfusionist to adjust roller pumps with greater accuracy and mainly repeatability in few minutes.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Extracorporeal Circulation/instrumentation , Infusion Pumps/standards , Allied Health Occupations , Calibration
9.
Rev. bras. eng. biomed ; 26(1): 25-32, abr. 2010. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-570336

ABSTRACT

As bombas de roletes ocupam um papel de destaque entre os dispositivos utilizados na circulação extracorpórea, pois são responsáveis pela movimentação do sangue. O ajuste adequado desses equipamentos é fundamental para minimizar o trauma nas células sanguíneas. O presente trabalho analisou dois métodos para ajuste das bombas: o método de medida de velocidade de queda e a calibração dinâmica em dois modelos de bombas, com o objetivo de avaliar as suas variações e limitações práticas de uso em centro cirúrgico. A velocidade de queda foi medida em dois modelos de bombas de roletes e em três pontos do leito rígido com valor final calculado pela média entre eles. A calibração dinâmica foi medida sequencialmente às medidas de velocidade de queda, e os valores médios de pressão foram registrados em arquivo, com intervalo entre medidas de 20 ms. Os valores médios de velocidade de queda mostraram diferenças significantes (p < 0,0007), quando comparados com os valores mínimos e entre os dois modelos de bombas. Nos dois métodos analisados foram observadas variações de ajuste entre os roletes, com possíveis consequências para a hemólise. A bomba 1 mostrou descentralização do leito rígido entre os pontos medidos (p < 0,02). O método de ajuste por medida de velocidade de queda mostrou erros em seus valores absolutos e com dificuldade de repetitividade e não foi possível estabelecer correlação com a respectiva medida de calibração dinâmica.


Roller pumps have an important role among the devices used in cardiopulmonary bypass, being responsible for pumping blood. The setting of pumps is essential to minimize the trauma on blood cells. This study examined two methods for pump adjustment: the drop rate method and dynamic calibration method, applied to two different pumps in order to evaluate their variations and practical limitations of use in operating room. The drop rate was measured in the lowest point of pump raceway (0º) and in two other points close to it (–20º and +20º) and the average values of the three points was also taken. The dynamic calibration was measured sequentially, and the pressure average values were recorded on file with a sampling interval of 20 ms. There were significant differences (p < 0.0007) in drop rate averages when compared with the lowest point in the two types of pumps. In two pumps were observed variations in settings between rollers with possible consequences for the hemolysis. The pump 1 showed decentralization in raceway between points measured (p < 0.02). The drop rate method showed errors in their absolute values and with limited repeatability, and it was not possible to correlate with their dynamic calibration measurements.


Subject(s)
Extracorporeal Circulation/instrumentation , Extracorporeal Circulation/standards , Calibration , Pulsatile Flow , Hemolysis , Hydrodynamic Models/methods , Cardiopulmonary Bypass/instrumentation
10.
Rev. bras. cir. cardiovasc ; 25(1): 51-58, Jan.-Mar. 2010. graf
Article in English, Portuguese | LILACS | ID: lil-552840

ABSTRACT

OBJETIVO: Processos inflamatórios e infecciosos mediados por bactérias em sítios distantes têm sido descritos como fator de risco à doença coronariana isquêmica aguda (DCIA). MÉTODOS: Cento e oitenta e um pacientes com DCIA, com e sem periodontites crônicas, foram incluídos neste estudo. Os pacientes foram admitidos no HC da UNICAMP e estratificados em três grupos: grupo 1 - pacientes com periodontite crônica grave (31 homens e 19 mulheres; média de idade 55,1 ± 11,29 anos); grupo 2 - pacientes com periodontite crônica leve (40 homens e 28 mulheres; média de idade 54,8 ± 10,37 anos); grupo 3 - pacientes desdentados (43 homens e 20 mulheres; média de idade 67,5 ± 8,55 anos). Amostras sanguíneas foram coletadas para mensurar os perfis lipídico, hematológico e glicêmico. Além disso, biópsias de 17 artérias coronárias com aterosclerose e igual número de artérias mamárias internas sem degeneração aterosclerótica no grupo 1 foram investigadas. Para análise estatística utilizou-se a análise de variância (ANOVA) e o teste de Scheffé para comparações múltiplas. RESULTADOS: Triglicérides e LDL estavam elevados no grupo 1 em relação ao grupo 2. O HDL apresentou-se reduzido em 20 por cento dos pacientes do grupo 1, e em 8 por cento nos desdentados. A glicemia estava elevada no grupo 1. DNA de bactérias periodontais foram detectados em 58,8 por cento das artérias coronárias. CONCLUSÕES: Pacientes com DCIA e periodontite crônica grave podem apresentar perfil lipídico alterado, como também microorganismos associados com as periodontites crônicas graves podem permear dentro de vasos coronarianos.


OBJECTIVE: Infectious and inflammatory processes mediated by bacteria in distant sites have been described as a risk factor for acute ischemic heart disease (AIHD). METHODS: One hundred one patients with AIHD with and without chronic periodontitis (CP) were included in this study. Patients were admitted to the HC UNICAMP and stratified into three groups: in group 1, we selected patients with severe chronic periodontitis (31 men and 19 women, mean age 55.1 ± 11.29 years old); the group 2 with mild chronic periodontitis (40 men and 28 women, mean age 54.8 ± 10.37 years old) and group 3 represented by the toothless (43 men and 20 women, mean age 67.5 ± 8.55 years old). Blood samples were collected to measure the lipid profiles, hematological and blood glucose levels. In addition, biopsies of seventeen coronary arteries with atherosclerosis and an equal number of internal mammary arteries without atherosclerotic degeneration in group 1 were investigated. Statistical analysis by analysis of variance (ANOVA) and Scheffé test for multiple comparisons was performed. RESULTS: Triglyceride and LDL levels were elevated in group 1 than in group 2. HDL were reduced by 20 percent in group 1 and remained reduced by 8 percent in toothless. Blood glucose was higher in group 1. DNA of periodontal bacteria was detected in 58.8 percent of the coronary arteries. CONCLUSIONS: Patients with (AIHD) and severe chronic periodontitis may have altered lipid profile, as well as microorganisms associated with CP can permeate into coronary vessels.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Chronic Periodontitis/complications , Myocardial Ischemia/microbiology , Acute Disease , Analysis of Variance , Blood Glucose/analysis , Case-Control Studies , Chlamydophila pneumoniae/genetics , Chlamydophila pneumoniae/isolation & purification , Chronic Periodontitis/blood , Coronary Vessels/microbiology , Coronary Vessels/pathology , DNA, Bacterial/blood , Lipids/blood , Mammary Arteries/microbiology , Mammary Arteries/pathology , Myocardial Ischemia/blood , Myocardial Ischemia/pathology
11.
Rev. bras. cir. cardiovasc ; 25(1): 59-65, Jan.-Mar. 2010. ilus, graf
Article in English, Portuguese | LILACS | ID: lil-552841

ABSTRACT

INTRODUÇÃO: A cirurgia cardíaca com circulação extracorpórea aumenta a permeabilidade vascular, com incremento da morbidade e da mortalidade pós-operatória. A ultrafiltração modificada na população pediátrica demonstrou melhora da função pulmonar e hemodinâmica, contudo benefício semelhante não está bem estabelecido em adultos. Nós temos a hipótese que a ultrafiltração modificada pode melhorar a função pulmonar, hemodinâmica e a coagulação no pós-operatório em pacientes adultos. MÉTODOS: Estudo prospectivo e cego para a equipe anestésica e da terapia intensiva em pacientes eletivos submetidos à revascularização do miocárdio. Todos os pacientes foram monitorados quanto à função hemodinâmica, pulmonar e hematológica no intraoperatório e até 48 horas de pós-operatório. Os pacientes foram divididos em dois grupos: um submetido à ultrafiltração modificada por 15 minutos após a saída de circulação extracorpórea e um grupo sem ser submetido à ultrafiltração. Os dados foram estudados com análise de variância com dois fatores para medidas repetidas. RESULTADOS: O grupo ultrafiltração modificada apresentou menor sangramento pós-operatório ao final de 48 horas (598 ± 123 ml vs. 848 ± 455 ml; P = 0,04) e menor necessidade de transfusão de unidades de hemácias (0,6 ± 0,6 unidades/ paciente vs. 1,6 ± 1,1 unidades/paciente; P =0,03). O grupo ultrafiltração apresentou menor resistência de vias aéreas quando comparado ao controle (9,3 ± 0,4 vs. 12,1 ± 0,8 cmH2O. L-1s-1; P =0,04) e menor complacência quando comparado ao controle (47,3 ± 2,0 mLcmH2O vs. 53,1 ± 3,1 mLcmH2O; P=0,04). CONCLUSÃO: O uso ultrafiltração modificada diminuiu o sangramento pós-operatório e a necessidade de transfusão, contudo sem diferenças no resultado clínico final. O uso da ultrafiltração modificada não foi associado com instabilidade hemodinâmica.


OBJECTIVE: The inflammatory response after cardiac surgery increases vascular permeability leading to higher mortality and morbidity in the post operative time. The modified ultrafiltration (MUF) had shown benefits on respiratory, and hemodynamic in pediatric patients. This approach in adults is not well established yet. We hypothesize that modified ultrafiltration may improve respiratory, hemodynamic and coagulation function in adults after cardiac surgeries. METHODS: A prospective randomized study was carried out with 37 patients who underwent coronary artery bypass graft surgery (CABG) were randomized either to MUF (n=20) at the end of bypass or to control (no MUF) (n=17). The anesthesia and ICU team were blinded for the group selection. The MUF were carried out for 15 minutes after the end of bypass. The patients data were taken at beginning of anesthesia, ending of bypass, ending MUF, 24 hours, and 48 hours after surgery. For clinical outcome the pulmonary, hemodynamic and coagulation function were evaluated. RESULTS: We observed lower drain loss in the MUF group compared to control group after 48 hours (598 ± 123 ml vs. 848 ± 455 ml; P=0.04) and required less red blood cells units transfusion compared to control group (0.6 ± 0.6 units/patient vs.1.6 ± 1.1 units/patient; P=0.03). The MUF group showed lower airway resistance (9.3 ± 0.4 cmH2O.L-1s-1 vs. 12.1 ± 0.8 cmH2O.L-1s-1; P=0.04). There were no deaths in both groups. CONCLUSION: The MUF reduces post operatory bleeding and red blood cells units transfusion, but with no differences on clinical outcome were observed. The routinely MUF employment was not associated with hemodynamic instability.


Subject(s)
Adult , Female , Humans , Male , Blood Coagulation/physiology , Blood Transfusion/statistics & numerical data , Coronary Artery Bypass , Hemodynamics/physiology , Hemofiltration/adverse effects , Respiratory Mechanics/physiology , Analysis of Variance , Chi-Square Distribution , Hemofiltration/methods
12.
Arq. bras. cardiol ; 94(1): 119-126, jan. 2010. graf, tab
Article in English, Spanish, Portuguese | LILACS | ID: lil-543868

ABSTRACT

Fundamento: A terapia de ressincronização cardíaca (TRC) é uma opção efetiva para os pacientes com insuficiência cardíaca (IC) avançada. Critérios clínicos, eletrocardiográficos e ecocardiográficos têm sido estudados na tentativa de selecionar os pacientes que serão beneficiados com a TRC, sendo o ecocardiograma um método utilizado tanto na seleção quanto na avaliação desta terapêutica. Objetivo: O objetivo deste trabalho é analisar a utilização do ecocardiograma na avaliação da TRC, no seguimento de dez dias e após dois anos de evolução. Métodos: Foram avaliados 20 pacientes submetidos à TRC, por um período de dois anos, sendo 80 por cento do sexo masculino. Foi aplicado o Questionário de Qualidade de Vida de Minnesota, o teste de caminhada de seis minutos e realizado o ecodopplercardiograma bidimensional. Dez dias após o implante do marca-passo biventricular, bem como dois anos depois, foi repetida a avaliação inicial. Resultados: Em dois anos, 5 pacientes (25 por cento) foram a óbito; 4 apresentavam cardiomiopatia de etiologia chagásica. Não houve alteração estatisticamente significante da fração de ejeção entre o período pré-operatório e os dez dias seguintes, mas sim uma alteração significante nos períodos de pré-operatório e dois anos e de dez dias e dois anos. No seguimento de dez dias, houve piora da dissincronia intraventricular avaliada pelo Doppler tecidual, assim como a pontuação no escore de qualidade de vida foi maior no grupo óbito. Conclusão: Dos parâmetros ecocardiográficos avaliados, somente a avaliação da dissincronia intraventricular pelo Doppler tecidual após o procedimento foi capaz de predizer a eficácia da TRC em relação à mortalidade.


Background: The cardiac resynchronization therapy (CRT) is an effective option for patients with advanced heart failure (HF). Clinical, electrocardiographic and echocardiographic criteria have been studied in an attempt to find the patients that will benefit from the CRT, considering that the echocardiogram is the method that is used both in the selection and in the assessment of such therapy. Objective: The objective of this work is to analyze the use of echocardiogram to assess the CRT, in a ten-day follow-up period and after two years of evolution. Methods: The assessment considered 20 patients subjected to CRT, for a period of two years, 80 percent of which were male. The Minnesota Living with Heart Failure Questionnaire (MLWHF) was filled out. Patients underwent a six-minute walking test. Then, the two-dimensional echo-Doppler-cardiogram was performed. The initial assessment was repeated ten days after and two year after the implantation of the biventricular pacemaker. Results: In two years, 5 patients (25 percent) died; 4 had cardiomyopathy caused by the Chagas's disease. There was no statistically significant change in the ejection fraction between the pre-operation period and the following ten days, but there was a significant change between the pre-operation period and two years after that, and the ten-day period and two years after that. In the ten-day follow-up period, there was the worsening of the intraventricular dyssynchrony, as evaluated by the tissue Doppler method, and the "living with heart failure" score was higher in the group of deaths. Conclusion: Out of the echocardiographic parameters assessed, only the intraventricular dyssynchrony assessment through the tissue Doppler method, after the procedure, was capable of predict the CRT efficiency with respect to the death rate.


Fundamento: La terapia de resincronización cardiaca (TRC) es una opción efectiva para los pacientes con insuficiencia cardiaca (IC) avanzada. Se vienen estudiando criterios clínicos, electrocardiográficos y ecocardiográficos en el intento de seleccionar a los pacientes que serán beneficiados con la TRC, siendo el ecocardiograma un método utilizado tanto en la selección como en la evaluación de este tratamiento. Objetivo: El objetivo de este trabajo es analizar la utilización del ecocardiograma en la evaluación de la TRC, en el seguimiento de diez días y luego de dos años de evolución. Métodos: Fueron evaluados 20 pacientes sometidos a la TRC, por un período de dos años, siendo el 80 por ciento de sexo masculino. Se aplicó el Cuestionario de Calidad de Vida de Minnesota, el test de caminata de 6 minutos y se realizó el ecodopplercardiograma bidimensional. Diez días tras el implante del marcapasos biventricular, así como dos años después, se repitió la evaluación inicial. Resultados: En dos años, 5 pacientes (25 por ciento) obitaron; 4 presentaban miocardiopatía de etiología chagásica. No hubo alteración estadísticamente significativa de la fracción de eyección entre el período preoperatorio y los diez días siguientes, pero sí una alteración significativa en los períodos de preoperatorio, dos años y diez días y dos años. En el seguimiento de diez días, hubo un empeoramiento de la disincronía intraventricular evaluada por doppler tisular, así como la puntuación en el escore de calidad de vida fue mayor en el grupo óbito. Conclusión: De los parámetros ecocardiográficos evaluados, solamente la evaluación de la disincronía intraventricular por doppler tisular tras el procedimiento fue capaz de predecir la eficacia de la TRC en relación a la mortalidad.


Subject(s)
Female , Humans , Male , Middle Aged , Cardiac Pacing, Artificial , Heart Failure , Analysis of Variance , Cardiac Pacing, Artificial/adverse effects , Exercise Test , Echocardiography, Doppler/methods , Follow-Up Studies , Heart Failure/mortality , Heart Failure/therapy , Quality of Life , Statistics, Nonparametric , Treatment Outcome , Ventricular Dysfunction, Left , Walking
13.
Rev. bras. cir. cardiovasc ; 24(4): 533-539, out.-dez. 2009. ilus, graf
Article in English, Portuguese | LILACS | ID: lil-540756

ABSTRACT

Objetivo: Um dos maiores danos causados pela oclusão em bombas de rolete é a hemólise. Estudos comparativos entre bomba de roletes com ajustes não oclusivos e bombas centrífugas têm sido realizados nas últimas décadas na tentativa de desenvolver novos produtos e ajustes que causem menos trauma aos elementos figurados do sangue. Comumente as bombas de rolete são ajustadas pelo método estático devido à preocupação com fluxos variáveis que podem ocorrer com ajustes não oclusivos. Folga excessiva nos roletes permite refluxo e pode acarretar erros no cálculo dos fluxos pela rotação da bomba, de acordo com os dispositivos adicionados ao circuito e a resistência sistêmica do paciente. O objetivo desse trabalho é avaliar o refluxo causado por dois modelos de bombas de rolete em aspirador de sangue e em reservatório de cardiotomia. Métodos: A visualização do refluxo foi realizada em aspirador de sangue e, em reservatório de cardiotomia, a visualização foi acompanhada de respectiva medida. Foram testados dois modelos de bombas de rolete de diferentes fabricantes, ajustadas pelo método de velocidade de queda e calibração dinâmica. Os testes foram conduzidos com tubos de silicone de 3/8 x 1/16 e 1/2 x 3/32 polegadas de diâmetro em água e solução análoga ao sangue. Resultados: Foram registrados visualmente os refluxos em aspirador de sangue e em reservatório de cardiotomia, com respectiva medida dos valores. As bombas apresentaram diferenças nos refluxos medidos ajustadas pelo método de calibração dinâmica. A bomba #2 apresentou refluxo, ajustada totalmente ocluída. Conclusão: Os refluxos medidos nos dois modelos de bomba apresentaram diferenças (P<0,008). Os resultados indicam diferenças nas características construtivas ocasionadas pelo processo de fabricação, projeto ou possíveis desgastes. Ajustes pouco oclusivos podem proporcionar variações nos fluxos com a resistência adicionada ao circuito, com dificuldade de correção do fluxo pelo incremento da rotação.


Objective: One of the major damage caused by occlusion in roller pumps is hemolysis. Comparative studies between roller pump with adjustments non occlusive and centrifugal pumps have been made in recent decades in an attempt to develop new products and adjustments that cause fewer traumas to the figurative elements of blood. Usually the roller pumps are adjusted by the static method due to concern variables flow that can occur with non-occlusive settings. Excessive slack in the rollers provoke back flow and can provides errors in the calculation of flow by the rotation of the pump, according to the devices added to the circuit and the systemic resistance of the patient. The objective of this study is to evaluate the back flow caused by two types of roller pumps in blood aspirator and cardiotomy reservoir. Method: Back flow visualization was performed in blood aspirator and cardiotomy reservoir. It was tested two different models of roller pumps, adjusted by drop rate and dynamic calibration. The tests were conducted with silicone tubes of 3/8 x 1/16 e 1/2 x 3/32 inches in diameter in water and solution similar to blood. Results: We recorded back flow visually in blood aspirator and in cardiotomy reservoir with their measure of values. The pumps had differences in refluxes measured adjusted by the dynamic calibration method. Pump#2 presents back flow adjusted fully occluded. Conclusion: The back flow measured in two models of pump present differences (P <0.008). The results indicate differences in its characteristics caused by the process of manufacturing, design or possible wear. Non-occlusive adjustments may cause variations in flow with the increase of resistance added to the circuit, with difficulty to fix the flow by increasing the rotation.


Subject(s)
Blood Circulation , Cardiopulmonary Bypass/instrumentation , Hemodynamics/physiology , Analysis of Variance , Calibration , Equipment Design
14.
Rev. bras. cir. cardiovasc ; 24(3): 382-390, jul.-set. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-533269

ABSTRACT

OBJETIVO: Identificar um método estatístico que expresse o tempo da presença do doente na sala de operação e construir a "matriz de relação" de otimização deste tempo, o tempo exato e real da operação. MÉTODOS: A análise de sobrevivência e o estimador de Kaplan-Meier permitiram calcular as curvas de sobrevivência para os diferentes tempos e a "matriz de relação" com 10 hipóteses para auxiliar na escolha da nova operação. A amostra aleatória simples de 71 indivíduos, das operações eletivas de adultos da Cirurgia Cardíaca/Hospital de Clínicas/UNICAMP, no ano 2008, no nível de confiança de 95 por cento. RESULTADOS: Os tempos das operações em média sobram em um intervalo de 140 a 200 minutos e excedem de 5 a 90 minutos. No geral, realizou-se em média diariamente uma operação dentro de 520 minutos, para um tempo disponível de 720 minutos. CONCLUSÃO: 1) Com o tempo máximo disponível de 720 minutos não é possível realizar operação, a não ser utilizando da "matriz de relação", sendo que o tempo máximo disponível varia entre 660 e 690 minutos, considerando-se intervalo de limpeza da sala. 2) O tempo do doente na sala de operação tem nele incluso o tempo de aprendizado pelo aluno, em um hospital escola, universitário. 3) Ao otimizar o tempo, mais doentes serão beneficiados, acarretando diminuição da fila de espera para novas operações. 4) A "matriz" de relação permite visualizar, opinar e decidir mediante várias hipóteses, resultando em melhor tomada de decisão


OBJECTIVE: To identify a statistical method that may express the patient length of stay in the operating room and build a "matrix of relationship" for optimizing this time, the real and exact time of the operation. METHODS: The analysis of survival and the Kaplan-Meier estimator allowed to calculate the survival curves for different times and the "matrix of relationship" with 10 hypothesis to help in choosing the new operation. The study consisted of a simple random sample of 71 patients, from elective operations for adults in Cardiac Surgery/Clinics Hospital/Unicamp, with confidence level of 95 percent in 2008. RESULTS: On average, the times of the operations over at a range of 140 minutes to 200 minutes and excess from 5 minutes to 90 minutes. In general, on average, one operation was daily performed within 520 minutes, for a time of 720 minutes. CONCLUSION: 1) With the maximum available time of 720 minutes is not possible to perform surgery, unless using the "matrix of relationship", whereas the maximum time available varies between 660 minutes and 690 minutes, considering the range of cleaning of the room. 2) The time of the patient in the operating room is a time that includes the time of learning by the student in an university hospital school. 3) When optimizing the time, most patients will benefit, causing a decrease from the waiting list for new opeartions. 4) The "matrix of relationship" allows to view and express opinion on a better decision making in addition to decide upon several assumptions


Subject(s)
Humans , Cardiac Surgical Procedures/statistics & numerical data , Length of Stay/statistics & numerical data , Operating Rooms , Aortic Aneurysm/surgery , Heart Defects, Congenital/surgery , Heart Valve Diseases/surgery , Myocardial Ischemia/surgery , Quality Assurance, Health Care , Survival Analysis , Time Factors
15.
Rev. bras. cir. cardiovasc ; 24(2): 188-193, abr.-jun. 2009. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-525550

ABSTRACT

OBJETIVO: Dentre os equipamentos utilizados em circulação extracorpórea, as bombas de rolete têm grande importância, com diversos modelos disponíveis de vários fabricantes. A calibração é um fator importante nas taxas de hemólise e o seu potencial difere em cada uma delas. Pesquisadores nem sempre abordam detalhes sobre os perfis do leito rígido, supondo que as formas padronizadas de calibração garantem valores iguais e comparáveis para todos os modelos de bombas de rolete. Dispomos principalmente de dois métodos para a calibração das bombas, o que também interfere com o potencial hemolítico. Nenhum dos métodos considera as características de impulsão do fluído, definido pela forma construtiva do leito rígido. O objetivo é avaliar o perfil hidrodinâmico de três modelos de bombas de roletes disponíveis no mercado brasileiro. MÉTODOS: A oclusão dos roletes foi feita por medidas de velocidade de queda e calibração dinâmica. Foram utilizados dois diferentes diâmetros de tubos de silicone (3/8 x 1/16 e 1/2 x 3/32 polegadas). RESULTADOS: Os perfis apresentaram diferenças em suas variâncias. P<0,01 para medidas de velocidade de queda e P<0,0001 para medidas de calibração dinâmica. Foram encontradas diferenças nas variações de pressão entre as bombas analisadas (P<0,002). CONCLUSÃO: As medidas de oclusão são dependentes da forma do leito rígido e comparações envolvendo bombas de rolete devem ser feitas com cautela. Testes com sangue deveriam ser realizados para verificar a influência das variações de pressão na hemólise.


OBJECTIVE: Among the equipments used in cardiopulmonary bypass the roller pumps have great importance with various models available from several manufacturers. The calibration is an important factor in hemolysis rates and its potential is different in each. Researchers do not always approach details on the pump bed profiles assuming that the standardized calibration settings ensure equal and comparable values for all models of roller pumps. We have mainly two methods for calibration of pumps which also interferes on the hemolytic potential. In both of them, the characteristics of fluid impulsion defined by the pump bed design are not considered. The aim of this study is to compare the hydrodynamic profile of three models of roller pumps available in the Brazilian market. METHODS: The rollers occlusion was performed by measures of drop and dynamic calibration. Two different silicone diameter tubes were used (3/8 x 1/16 and 1/2 x 3/32 inches). RESULTS: The profiles showed differences in their variances, P<0.01 for drop rate measures and P<0.0001 for dynamic calibration. Different changes in pressure were found between the pumps analyzed (P<0.002). CONCLUSION: The measures of occlusion are dependent on the design of the pump bed and comparisons involving roller pumps should be performed with caution. Blood tests should be performed to verify the influence of changes in hemolysis pressure.


Subject(s)
Cardiopulmonary Bypass/instrumentation , Pulsatile Flow/physiology , Analysis of Variance , Brazil , Calibration , Equipment Design , Linear Models
16.
Rev. adm. saúde ; 11(43): 83-91, abr.-jun. 2009. tab, ilus
Article in Portuguese | LILACS | ID: lil-574998

ABSTRACT

Objetivo: Planejamento do aumento das operações cardíacas, com repercussão na fila de espera, através de um estudo de metodologias de apoio, método estatístico e um método de gestão da qualidade, aplicados ao tempo da presença do doente na sala de operação. Métodos: Com o usod e um método estatístico, a a nálise de sobrevivência, utilizando o estimador de Kaplan-Meir, calcular as curvas de sobrevivência para os tempos do procedimento cirúrgico. Concomitantemente fazer uso do método de gestão da qualidade, empregando o conceito de "matriz de relação", com os resultados dos tempos da presença do doente na sala de operação, com 10 cenários possíveis, permite-se planejar a otimização da sala de cirurgia cardíaca, com previsão de novas operações, através do tempo de presença do doente na sala de operação, com repercussão na fila de espera das operações cardíacas geradas pela suspensão de operações. Para a análise dos resultados relativos à suspensão de operações, foi utilizado o diagrama de Pareto, outra ferramenta da gestão da qualidade. Resultados e discussões: Para suspensão de operações no ando de 2008, houve 39 por cento suspensas, sendo que 81 por cento dos motivos foram "hospitalares extrapacientes" e 19 por cento "relativos ao paciente". O tempo que sobra das operações cardíacas está em média no intervalo de 140 a 200 minutos e o tempo que excede está no intervalo de 5 a 90 minutos, para a realização de novas operações. Realizaou-se em média diariamente uma operação dentro de 520 minutos, para um tempo disponível de 720 minutos. No tempo de limpeza da sala foram considerados os tempos por cada tipo de operação cardíaca, além do que é estabelecido pela literatura. O tempo para agilização para novas operações junto às áreas teve como regra o tempo máximo de 60 minutos em relação ao tempo máximo da operação. Conclusão: a criação de um quadro de metodologias de apoio para agendamento de operações possibilia o uso concomitante de um método estatístico...


Objective: Preparation of increased cardiac operations, with repercussions on the waiting list, through a study of methods of support, statistical method and a method of quality management, applied to the time of the presence of the patient in the operating room. Methods: Using a statistical method, analysis of survival using the Kaplan-Meir estimator to calculate thesurvival curves for the time of surgery. Concurrently using the method of quality management, using the term “matrix of relationships.” When using the results of the analysis of survival, to compose the “matrix of relationship “with the outcome of stroke patients in the presence of the operating room, with 10 scenarios, the optimization of the design allows room for cardiac surgery, with estimates of new business, over time the presence of the patient in the operating room, with repercussions on the waitinglist for heart operations generated by the suspension of operations. For the analysis of results for the suspension of operations, was used for Pareto diagram, another tool of quality management. Results and discussions: For suspension of operations in the year 2008, was suspended 39%, with 81% of the reasons were “reasons extrapacientes hospital and 19%” for the patient. “The time left cardiac operations is on average within 140 minutes to 200 minutes and the time that is beyond the range of 5 minutes to 90 minutes to carry out new operations. In general, took place in an average daily...


Subject(s)
Humans , Total Quality Management , Survival Analysis , Operating Rooms , Thoracic Surgery , Time
17.
Rev. bras. cir. cardiovasc ; 23(2): 224-234, abr.-jun. 2008. ilus, graf
Article in English, Portuguese | LILACS | ID: lil-492975

ABSTRACT

OBJETIVO: Verificar, em modelo experimental de coração isolado de suínos, se a associação da trimetazidina à solução cardioplégica promove melhora no desempenho do coração. MÉTODOS: O modelo experimental utilizou suínos Large-White, com coração isolado perfundido por suporte de outro animal em modo de execução de trabalho ("working heart state"). Foram divididos em três grupos (n = 6), submetidos a isquemia regional seguida de isquemia global, que recebiam um dos três tratamentos: solução St Thomas (ST), solução St Thomas acrescida de trimetazidina (TMZ) e grupo controle (Co). Durante período de reperfusão, aos 30, 60 e 90 minutos, foram medidos parâmetros hemodinâmicos de contratilidade e metabólicos, obtendo-se assim a elastância máxima (Emáx), o índice de trabalho sistólico pré-recrutável (PRSW), "dureza" do ventrículo (EDPRV), fluxo coronariano, consumo de oxigênio e dosagens de lactato e glicose. Os resultados foram analisados estatisticamente. RESULTADOS: Em relação aos parâmetros hemodinâmicos de contratilidade, não houve diferença estatística significante entre os três grupos. Houve produção crescente de lactato nos três grupos de forma uniforme quanto maior o tempo de reperfusão. O fluxo coronariano, o consumo de oxigênio e o consumo de glicose tiveram grande variação entre os diferentes tempos medidos, mas sem diferença entre os três tratamentos. O peso final do ventrículo esquerdo foi significativamente menor no grupo trimetazidina (TMZ) do que nos demais. CONCLUSÃO: A administração da trimetazidina associada como adjuvante à solução cardioplégica, sem pré-tratamento, não demonstrou benefício hemodinâmico ou metabólico em modelo experimental "working heart" de coração isolado em porcos.


OBJECTIVE: The aim of this study is to verify in an isolated working heart swine model if the acute administration of trimetazidine to cardioplegia, without pre=treatment improves heart performance. METHODS: Eighteen pairs of swines were used in this working heart model, divided into three groups (n = 6) that underwent regional and global ischemia. Each group was selected to a different treatment: St Thomas cardioplegia (ST), St Thomas enriched with trimetazidine (TMZ) and control group (Co). Data was collected during reperfusion period at 30, 60 and 90 minutes. Hemodinamic parameters such as elastance contractility index (Emax), preload recruitable stroke work relationship (PRSW) and heart "stiffness" (EDPVR) were measured. Other data included coronary flow, lactate, oxygen and glucose consumption. Results were statistically analyzed. RESULTS: All contractility data were not significantly different among three groups. Lactate became constantly higher according to time uniformly in all three groups. Coronary flow, glucose consumption and oxygen consumption presented large variations during time periods but according to treatments showed no statistical differences in all three groups. Left ventricle final weight was significantly lower in trimetazidine group compared to both other groups. CONCLUSION: Administration of trimetazidine enhanced cardioplegia, without pre-treatment, showed no hemodinamic or metabolic improvement in swine isolated working heart model.


Subject(s)
Animals , Female , Cardioplegic Solutions/pharmacology , Models, Cardiovascular , Myocardial Contraction/drug effects , Myocardial Ischemia/metabolism , Trimetazidine/pharmacology , Analysis of Variance , Bicarbonates/pharmacology , Calcium Chloride/pharmacology , Hemodynamics/drug effects , Lactic Acid/metabolism , Models, Animal , Myocardial Reperfusion , Magnesium/pharmacology , Myocardial Contraction/physiology , Oxygen Consumption/drug effects , Oxygen Consumption/physiology , Perfusion/methods , Potassium Chloride/pharmacology , Swine , Sodium Chloride/pharmacology , Time Factors
18.
Rev. bras. cir. cardiovasc ; 23(2): 175-182, abr.-jun. 2008. ilus, tab
Article in English | LILACS | ID: lil-492989

ABSTRACT

OBJECTIVE: To investigate the effectiveness of ultrafiltration in removing inflammatory mediators released by cardiopulmonary bypass and to correlate ultrafiltration with alterations in organic function according to the Sequential Organ Failure Assessment Score. METHODS: Forty patients were included and randomized into two groups: "no ultrafiltration" (n=20; Group I) and "ultrafiltration" (n=20; Group II). Activated complement 3 and 4, interleukins 1beta, 6, 8 and tumor necrosis factor alfa were measured prior to anesthesia induction (Time 1), 5 minutes before cardiopulmonary bypass (Time 2), in the ultrafiltrated fluid (Time 3), 30 minutes (Time 4), and 6 (Time 5), 12 (Time 6), 24 (Time 7), 36 (Time 8) and 48 (Time 9) hours following cardiopulmonary bypass. Sequential Organ Failure Assessment Score was evaluated at Time 1, 6 and 9. Statistical significance was established at p < 0.05. RESULTS: In the ultrafiltrated fluid, only tumor necrosis factor alfa levels were detected. Levels of activated complement 3 at Times 5 and 7 and activated complement 4 at Times 5 and 6 were significantly higher in the unfiltered Group, and levels of interleukin 6 were higher in the filtered Group at Times 7 and 8. Interleukins 1beta, 8, tumor necrosis factor alfa, and the Sequential Organ Failure Assessment score were not significantly different between the groups. CONCLUSIONS: Ultrafiltration significantly filtered tumor necrosis factor alfa but did not influences serum levels of this cytokine. Ultrafiltration with the type of filter used in this study had no effect in organic dysfunction and should be used only for volemic control in patients undergo cardiopulmonary bypass.


OBJETIVO: Investigar a eficácia da ultrafiltração na remoção de mediadores inflamatórios liberados pela circulação extracorpórea e correlacionar ultrafiltração com alterações da função orgânica de acordo com o "Sequencial Organ Failure Assessment Score". MÉTODOS: Quarenta pacientes foram incluídos e randomizados em dois grupos: "sem ultrafiltração" (n=20; Grupo I) e "ultrafiltração" (n=20; Grupo II). Complementos 3 e 4 ativados, interleucina 1beta, 6, 8 e fator de necrose tumoral alfa foram dosados antes da indução anestésica (T1), 5 minutos antes da circulação extracorpórea (T2), no líquido ultrafiltrado (T3), 30 minutos (T4), 6 (T5), 12 (T6), 24 (T7), 36 (T8) e 48 (T9) horas após término da circulação extracorpórea. "Sequencial Organ Failure Assessment Score" foi avaliado nos tempos 1, 6 e 9. Significância estatística foi estabelecida com p < 0,05. RESULTADOS: No líquido ultrafiltrado, apenas níveis de fator de necrose tumoral alfa foram detectados. Níveis de complemento 3 ativado, nos tempos 5 e 7, e complemento 4 ativado, nos tempos 5 e 6, foram significativamente elevados no grupo sem ultrafiltração, e níveis de interleucina 6 foram elevados no grupo ultrafiltrado, nos tempos 7 e 8. Interleucina 1beta, 8, fator de necrose tumoral alfa, e "Sequencial Organ Failure Assessment Score" não tiveram diferenças significantes entre os grupos. CONCLUSÕES: Ultrafiltração filtra significativamente fator de necrose tumoral alfa, mas isto não influencia nos níveis séricos desta citocina. Ultrafiltração com o tipo de filtro usado neste estudo não tem efeito na disfunção orgânica e deverá ser usada apenas para controle volêmico nos pacientes submetidos à circulação extracorpórea.


Subject(s)
Female , Humans , Male , Middle Aged , Coronary Artery Bypass , Cardiopulmonary Bypass/adverse effects , Hemofiltration/standards , Inflammation Mediators/blood , Multiple Organ Failure/diagnosis , Chi-Square Distribution , /analysis , /analysis , Enzyme-Linked Immunosorbent Assay , Interleukin-1beta/blood , /blood , /blood , Prospective Studies , Time Factors , Tumor Necrosis Factor-alpha/blood
19.
Arq. bras. cardiol ; 90(4): e21-e23, abr. 2008. ilus
Article in English, Portuguese | LILACS | ID: lil-482962

ABSTRACT

Descrevemos caso de paciente do sexo masculino, 49 anos, que sofreu ferimento por arma de fogo no tórax, transfixando o mediastino médio. Apresentava-se estável hemodinamicamente, contudo taquicárdico e taquipnéico. Ele foi submetido à propedêutica armada com radiograma de tórax, ecocardiografia transtorácica, tomografia computadorizada de tórax e arteriografia do arco aórtico. Evidenciou-se fístula traumática do tronco braquiocefálico com a veia braquiocefálica. Realizou-se correção cirúrgica com a utilização de circulação extracorpórea e hipotermia profunda com parada circulatória total. O paciente evolui bem com alta no quinto pós-operatório.


We describe the case of a 49-year old male patient who suffered a gunshot wound in the chest which transfixed the medial mediastinum. He was hemodynamically stable, but had tachycardia and tachypnea. He was submitted to integrated work-up with chest radiogram, transthoracic echocardiography, computerized chest tomography, and arteriography of the aortic arch. A traumatic fistula was evidenced between the brachiocephalic trunk and the brachiocephalic vein. Surgical repair was performed using extracorporeal circulation and deep hypothermia with total circulatory arrest. The patient progressed well and was discharged on the fifth day postoperatively.


Subject(s)
Humans , Male , Middle Aged , Arteriovenous Fistula , Brachiocephalic Trunk/injuries , Brachiocephalic Veins/injuries , Wounds, Gunshot/complications , Arteriovenous Fistula/etiology , Brachiocephalic Trunk , Brachiocephalic Veins
20.
Rev. bras. cir. cardiovasc ; 23(1): 14-22, jan.-mar. 2008. ilus, graf
Article in English, Portuguese | LILACS | ID: lil-489694

ABSTRACT

OBJETIVO: Desenvolver modelo de coração isolado de suíno "working heart" sob suporte por circulação parabiótica e verificar se o mesmo é estável e se possibilitou de forma efetiva a mensuração dos dados propostos. MÉTODOS: O modelo foi padronizado durante preparação para estudo de associação de agente à solução cardioplégica. Foram realizados 18 experimentos com um animal suporte e um animal doador em cada. O coração do animal doador foi perfundido como coração isolado pelo animal suporte em modo de execução de trabalho ("coração ejetante"). O coração isolado foi submetido à isquemia regional por pinçamento da artéria interventricular anterior seguido de isquemia global. Durante reperfusão, com o coração ejetante (em modo "working heart"), aos 30, 60 e 90 minutos foram medidos parâmetros hemodinâmicos de contratilidade e metabólicos, obtendo-se assim a elastância máxima (Emáx), o trabalho sistólico pré-recrutável (PRSW), rigidez do ventrículo (EDPRV), fluxo coronariano, consumo de oxigênio e dosagens de lactato e glicose. RESULTADOS: Os animais suporte ficaram estáveis durante todo o experimento. O pH, a pressão parcial de oxigênio e o hematócrito foram mantidos estáveis e dentro da faixa fisiológica. O coração isolado foi perfundido de forma adequada durante todo o experimento. Os dados hemodinâmicos e metabólicos propostos puderam ser mensurados adequadamente e sempre com o coração ejetante, em modo de execução de trabalho ("working heart"). CONCLUSÃO: O modelo de coração isolado desenvolvido tipo "working heart" se manteve estável durante todo o experimento, sem a administração de drogas cardiotônicas e possibilitou a mensuração de todos os dados propostos de forma efetiva com o coração executando trabalho.


OBJECTIVE: To develop an isolated working heart model with parabiotic circulaton in swines and verify its stability and possibility to allow effective measurements of hemodinamic and metabolic data. METHODS: This model was developed during study of association of agents to cardiolegia. There were performed 18 experiments, each with a support animal and a donor animal. Donor animal heart was perfused as isolated working heart with parabiotic circulation from support animal. Isolated heart underwent regional ischemia by interventricular artery clamping, followed by global ischemia. During reperfusion in working heart state mode at 30, 60 and 90 minutes, contractility indices such as elastance, preload recruitable stroke work index and metabolic data were acquired. RESULTS: Support animals were kept stable throughout the procedures without use of blood transfusions or vasoactive drugs. pH, oxygen partial pressure and hematocrit were kept stable and within physiologic ranges. Isolated heart was perfused adequately throughout the experiment. All hemodinamic and metabolic data proposed were adequately measured in working heart state mode. CONCLUSION: This swine isolated "working heart" model was kept stable throughout the experiments with no administration of vasoactive drugs and it allowed adequate measurements of metabolic and hemodinamic data.


Subject(s)
Animals , Female , Cross Circulation , Heart/physiology , Models, Animal , Myocardial Contraction/physiology , Myocardial Reperfusion/methods , Bicarbonates/administration & dosage , Calcium Chloride/administration & dosage , Hemodynamics , Hydrogen-Ion Concentration , Magnesium/administration & dosage , Myocardium/metabolism , Potassium Chloride/administration & dosage , Swine , Sodium Chloride/administration & dosage